Anjue Profile |
Anjue Culture |
Anjue Overview |
Anjue Profile |
Anjue Culture |
Anjue Overview |
Production Base |
Quality Control |
R & D |
News & Events |
Recommend |
Promotion |
Ambulance |
Medical Vehicle |
Hospital Solution |
Distributors |
OEM & ODM |
Client Say |
After Sales |
Video |
Download |
Contact Details |
Your position:Home > Products > Veterinary Equipments > Veterinary X Ray Machine
32kW 400mA Veterinary X Ray Machine AJ-VX400
(Suitable for Big Animals)
32kW 400mA Veterinary X Ray Machine Digital Type with Wireless Flat Panel
32kW 400mA Veterinary X Ray Machine Digital Type with Wired Flat Panel
32kW 400mA V Mobile Veterinary X Ray Machine Analog Type
32kW 400mA Veterinary X Ray Machine Digital Type Parameters
Power |
32kW (can take clear images for the body no more than 50cm thickness ) |
|
Power supply |
Single-phase,220V 50/60HZ (wire diameter>4mm², internal resistance<0.5Ω) |
|
mA |
10~400 mA |
|
mAS |
1~400mAS, stepping by R’10 |
|
KV |
40~125kV, stepping by 1kV |
|
Exposure time |
0.003~6.3S adjustment: Increased /reduced by 1mS each time |
|
X-ray tube |
Chinese brands Mingwei M7110 are available or Toshiba tube for options .0.6-1.2mm double focus |
|
Anode rotating speed/Anode heat capacity |
2800prm/140kHU |
|
Generator frequency |
400kHz |
|
Radiography table(W*L cm) |
Width: 70cm, length: 140/120cm (either) urinary trough can be equipped with |
|
Flat panel detector |
Imaging area |
17*17 inches (or 14*17 inches) (wired and wireless) |
Pixel size |
140um |
|
A/D conversion |
16bits |
|
Spatial resolution |
3.6lp/mm |
|
Software |
Veterinary software |
|
Computer configuration |
Intel i5 processor; 8G memory, 2G discrete graphics card, 128G solid state drive + 1TB mechanical hard drive, PCI-E and Ethernet dual Gigabit network cable interface, R232 interface; 22.5-inch Dell professional small dot pitch monitor; operating system: win10 |
Digital Images
*Images from different brand X-ray tube
(Toshiba 7242 tube 50kv 0.8mAS ) (Chinese brand tube 50kv 0.8mAS)
*High quality flat panel dector with good performance to present item’s details
(Picture shows high-contrast rendering of fishbone fine fibers)
(Picture shows Animals Belly Image)
Installation Instructions
1. X-ray room: 20m2 room is recommended.
2. Lead glass size recommended: 40*60cm or 60*80 cm
3. X-ray protection preparation: use barium sulfate powder or lead sheet for the wall of the room, and lead sheet for the ceiling;
4. A fan must be installed on the top to facilitate the discharge of ionized air
5. All surfaces of the x-ray room that people can reach need to be covered with lead sheet or barium sulfate powder. If it is the first floor, the ground does not need to be covered; if it is the top floor and will not polluted the environment, lead protection is not required.